Landfill/Digester Gas Thermal Oxidizers

PCC has supplied thermal oxidizers to the landfill gas industry for nearly 30 years.

A landfill gas thermal oxidizer destroys the tail gas, or waste gas, left over when landfill gas is upgraded to high-Btu gas, which is also sold as renewable natural gas (RNG). The separation system retains the methane and rejects other components: carbon dioxide, water vapor, VOCs, and any methane that passes through the separation process. That reject stream generally cannot be vented directly, and it often has too little heating value to burn on its own.

The reject stream is also subject to fluctuations. Several streams arrive at different pressures, the composition shifts as the plant cycles, and the gas can briefly become fuel-rich when pressure swing adsorbers vent. PCC designs the thermal oxidizer to accommodate these variations.

PCC Modern Landfill Diagram, landfill gas thermal oxidizer

Destruction efficiency (DRE) up to 99.99%

Burners that fire natural gas, raw landfill gas, or partially processed high-Btu gas from the plant

Dual burners for reliable on-line service, and high turndown with multiple burners

Direct injection of the permeate waste stream

Refractory selected for long service life

Integrated Train:

  • Heat exchanger supplying heated streams to regenerate the media beds in the gas processing plant

  • Combustion air preheat to minimize burner fuel

  • Waste heat boiler option where the plant can use steam

  • Nozzles provided for heat recovery to be added later

Contact us by phone at (412) 655-0955 or request an engineering consultation to discuss your landfill gas project.

Need Information? Tell us your request.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*
Max. file size: 20 MB.
Would you like to request a quotation?

Why the Waste Gas Composition Comes First

Raw landfill gas is roughly 50 percent methane and 50 percent carbon dioxide, with a small amount of non-methane organic compounds. Once the upgrading plant has captured the bulk of the methane, the oxidizer receives about half of the raw gas flow, which is mostly carbon dioxide. Carbon dioxide adds no heat and requires heat to bring up to temperature, so the oxidizer runs on support fuel most of the time. How much support fuel depends on how much methane slips past the separation system.

Operating exceptions determine much of the remaining design. When an adsorber vents, the stream can go from inert to exothermic in moments, and the burner, the air supply, and the controls must respond without losing destruction efficiency or overheating the chamber. PCC designs the oxidizer to meet its emission targets throughout the operating range, rather than at one single design point. For gas collected under EPA’s landfill standards, the control requirement is a 98 percent reduction in non-methane organic compounds or an outlet concentration of 20 ppmv as hexane.

What the Tail Gas Oxidizer Receives and What the Design Does About It

Condition What It Does in the Oxidizer Design Response
Carbon dioxide-rich waste gas with trace VOCs Absorbs heat and will not sustain combustion Support fuel burner firing natural gas, raw landfill gas, or high-Btu gas; combustion air preheat
Adsorber vent that is briefly fuel-rich Releases heat suddenly Controls and burner turndown that follow the swing
Membrane permeate A continuous low-heating-value stream Injected directly into the oxidizer
Several streams at different pressures Flow and composition change continuously Simple controls for reliability
Landfill gas production that rises, then declines The required capacity changes over the life of the site Sized for the maximum flow, with turndown for the early and late years

Heat Recovery for the Gas Plant

The oxidizer exhaust is a high-temperature heat source the upgrading plant can use. A heat exchanger on that exhaust can supply heat for regenerating the plant’s media beds, which may be essential to the upgrading process. Heat recovery can also preheat the burner’s combustion air and reduce fuel use.

Where heat recovery is not justified in the first phase of the process, the unit can be built with flanged nozzles so that an exchanger or boiler can be added later. Siloxanes in landfill gas form silica when they burn, which can foul heat transfer surfaces, so the siloxane content of the tail gas is an important consideration in the heat recovery design.

Where PCC Landfill Gas Oxidizers Operate

  • Landfill gas to high-Btu gas (RNG) plants

  • Landfill gas to compressed natural gas (CNG) fuel projects

  • Methane digester plants for agricultural or municipal applications

  • Plants using membrane or pressure swing adsorption separation supplied by others

In one PCC project, the plant started at about 3,000 scfm of raw landfill gas and was expected to reach nearly 6,000 scfm, with the oxidizer handling 1,500 to 3,000 scfm of waste gas. The project cut the landfill’s methane venting by 16,500 tons per year and was designed to produce 25,000 gallons of CNG per day at the initial flow. The case history provides additional details.

What PCC Needs to Size a System

  • Raw landfill gas flow now

    and the projected maximum

  • The separation technology:

    membrane, pressure swing adsorption, or both

  • Each waste stream’s flow, pressure, and composition,

    including methane content

  • How the streams change

    during adsorber venting, startup, and upset

  • Sulfur and siloxane content of the gas

  • Fuels available for the burner

  • Heat the plant needs

    and at what temperature

  • Destruction efficiency and emission limits

    in the air permit

Where the separation system is still being designed, an engineering study works out the range of waste gas conditions with the plant designer before the oxidizer is specified.

Frequently Asked Questions